Nickel Titanium Shape Memory Alloy Wire

Nickel Titanium Shape Memory Alloy Wire

Grade:Nickel titanium shape memory alloy wire
Quality:Standard quality
Size: According to your needs
Packaging :Standard shipping and careful package
Payment Terms:T/T, L/C,or as required
Type Of Shipping:by air/ by ocean /by railway
Certificates: ISO 9001:2015/EN10204 3.1 MTC/EN10204 3.2 MTC
Send Inquiry
product introdction


Nickel titanium shape memory alloy wire, commonly known as Nitinol wire, is a specialized metal alloy consisting of approximately 55% nickel and 45% titanium. It is renowned for its two remarkable properties: shape memory and superelasticity. Shape memory refers to the ability of the wire to return to a predefined shape when heated above its transformation temperature, while superelasticity allows it to undergo significant deformation and revert to its original form without permanent damage when the stress is released. These properties result from a reversible phase change between the martensitic and austenitic structures of the alloy. Nitinol wires typically have transformation temperatures ranging from -20°C to 100°C, depending on their composition and treatment.

 

Products features

 

Shape Memory Effect
Nickel titanium shape memory alloy wire has the shape memory effect, which allows the wire to return to a predefined shape after being deformed when heated above a certain temperature. This transformation temperature typically ranges from -20°C to 100°C, depending on the specific composition of the alloy, particularly the ratio of nickel to titanium. For example, a higher nickel content tends to lower the transformation temperature. In medical applications like stents, Nitinol wire is inserted in a compressed form, and once inside the body (where the temperature is higher), it expands to its original shape, fitting snugly into blood vessels.

 

Superelasticity
Another significant feature of nickel titanium shape memory alloy wire is superelasticity, the ability to undergo large strains-up to 8%-and recover its original shape without permanent deformation when the stress is removed. This is a result of a phase transition between martensitic and austenitic forms in the alloy. For example, Nitinol wires are used in orthodontics to create braces that can adjust themselves to the shifting positions of teeth, providing continuous gentle pressure. This elasticity reduces the need for frequent adjustments and increases comfort for the patient.

 

Biocompatibility
Nickel titanium alloys are biocompatible, meaning they can safely be used in contact with human tissues without causing adverse reactions. This makes Nitinol wire ideal for medical implants and devices such as guidewires and bone staples. Its corrosion resistance ensures long-term stability in bodily fluids, a critical requirement for medical devices that remain inside the body for extended periods.

 

High Fatigue Resistance
Nitinol wire has high fatigue resistance, which means it can withstand repetitive cycles of deformation and return to its original shape without losing its properties. This durability is crucial in applications where the material experiences frequent and repeated stress, such as in actuators or in medical devices like heart valves, where the wire must endure millions of operational cycles without failing. The ability to maintain performance over a long lifespan makes Nitinol a reliable choice for dynamic environments.

 

Product name

Nitinol wire niti wires with shape memory alloy and super-elastic

Model Number

Niti-01

Application

Medical, Industry

Grade

Tianium & nickel alloy

Ti (Min)

45%

Strength

950 MPa

Processing Service

Bending, Welding, Decoiling, Cutting, Punching, Shaping

Feature

shape memory alloy and super-elastic

Material

55% Nickel and 45% Titanium

Af range

subzero 30C to 100C

Diameter range

0.05 mm to 5 mm

Surface

Black bright and polished

Stock

various diameter are on stock

Usage

spring, paper clip, fishing, medical device etc.

Nitinol wire&rod

round and flat wire

Key word2

nitinol memory wire for sale

Key word3

nitinol wire

 

 

Technical parameters

 

Standard: Q/XB1516 Q/XB1520
Grade: TiNi-01, TiNi-02, TiNi-SS, TiNi-03, TiNi-YY, TiNi-cu, TiNi-nb
Phase change temperature:
TiNi-01 phase change temperature is 20℃-40℃;
TiNi-02 phase change temperature is 45℃-90℃;
TiNi-SS phase change temperature: 5℃-15℃;
TiNi-03 phase change temperature lt;5℃;
tini-yy phase change temperature: 33℃±3℃;
tinicu phase change temperature: as-ms≤5℃;
tininb phase change temperature: as-ms<150℃
Physical properties of nickel-titanium alloy: tensile strength: 850MPa; yield strength: 195~690MPa; elongation: 25~50%
Chemical composition of nickel-titanium alloy memory wire: Ni: 55.4%--56.2%, C≤0.07, H≤0.005, O≤0.050, N:≤ 0.05

 

Products Display   

 

NI-Ti alloy Shape Memory Alloy wire

 
Nickel titanium alloy
 

 

Hot Tags: nickel titanium shape memory alloy wire, China nickel titanium shape memory alloy wire manufacturers, suppliers, factory, titanium welding wire, thin titanium wire, gr2 titanium wire

Send Inquiry